Medical Bubble Infant CPAP with Air Compressor (AD-I)

Customized: Non-Customized
Certification: CE, EEC, ISO13485
Scale: Medium
Type: Breathing Apparatus
Product Name: Infant CPAP Machine
Pressure of Oxygen and Air: 0.3MPa~0.4MPa
Customization:
Diamond Member Since 2009

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AD-I
Noise
<52dB(a)
Power
220V AC 50Hz
Warranty
12 Months
Lead Time
Within 7days
Transport Package
Strong Packing
Specification
CE ISO TUV
Trademark
PIOWAY
Origin
China

Product Description

Medical  Bubble Infant CPAP with Air Compressor (AD-I)

Medical Bubble Infant CPAP with Air Compressor (AD-I)


Main Features:
Bubble CPAP is a sort of special medical equipment for supporting of babies' breath which devised and manufactured based on the wide application of closed continuous NCPAP in department of pediatrics. It uses on the course of ventilation treatment of Nasal-CPAP for premature, neonate, infant to children below 14 year old. The mode of CPAP can reduce babies' WOB effectively, while keeping the autonomous respiration well.

Superiority:
Supply a safe and controllable FIO2;
Keep the FRC effectively;
Reduce infant's WOB;
Reduce the need of invasive mechanical ventilation;
Supply better warm and humid gas;
Reduce the occurrence rate of the CLD;
Improve the physical sighs, such as height, weight.
Matching solution of Medical Air Compressor:
Max exhausting pressure: 0.7MPa
Output pressure: 0.20MPa~0.30MPa
Flow: >25L/ruin
Noise: <52dB(A)


Performance parameter:
FIO2: 21%~100%
Flow: 0~18LPM
CPAP pressure: 0.3~1.0kPa(3~10cmH2O)
Water capacity of Generator: 500ml or more
Alarm:the differential pressure> 0.1MPa, sound alarm


Common parameter:
Pressure of oxygen and air: 0.3MPa~0.4MPa
Power: 220V AC 50Hz
Certification: ISO 13485 CE


Parts:
Matching with Medical Electric Respiratory humidifier(PN-2000F/FA)
Working temperature: 30ºC~37ºC
Max temperature of heating plate: 85ºC
Capacity of Chamber:280ml(F-Adult); 230ml(FA-Infant)
Max flow: 180L/min
Max working pressure: 2kPa


CPAP Generator:
1. It is easy to set the oscillating gas pressure from 3cmH2O to 10cmH2O through adjusting the CPAP pressure bar.
2. The automatic regulating mechanism of water-level ensure the constant CPAP pressure.
3. The dismountable chamber is very convenient.

 