Electronic Portalbe Infusion Pump (OIP-900)

Product Details
Customization: Available
Customized: Non-Customized
Certification: CE, FDA, ISO13485
Still deciding? Get samples of US$ 200/Piece
Request Sample
Manufacturer/Factory, Trading Company
Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Electronic Portalbe Infusion Pump (OIP-900)
  • Electronic Portalbe Infusion Pump (OIP-900)
  • Electronic Portalbe Infusion Pump (OIP-900)
  • Electronic Portalbe Infusion Pump (OIP-900)
  • Electronic Portalbe Infusion Pump (OIP-900)
Find Similar Products

Basic Info.

Model NO.
OIP-900
Type
Infusion Pump
Purge Rate
800 Ml/H
Infusion Volume Range
1 Ml~9999.9 Ml (Step: 0.1 Ml)
Kvo Rate
1 Ml/H (1~300 Ml/H); 3 Ml/H (Greater Than 300 Ml/H
Time Range
1 Min~9999 Min (Step: 1 Min)
Warranty
12 Months
Lead Time
Within 7 Days
Transport Package
Strong Packing
Trademark
PIOWAY
Origin
China

Product Description

OIP-900 Infusion Pump
Electronic Portalbe Infusion Pump (OIP-900)
 

 
Features: 
1. 4.3 inch color LCD with backlight
2. Three working modes: Rate/Volume/Time mode
3. Purge, KVO function
4. Heating and remote control functions
5. Audible and Visible alarms
6.Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle
7. Calibration function, suitable for any brand disposable IV set

Technical Specifications: 
Pump Type: Drip type infusion pump

Pumping Way: Peristalic fingers

Adjustable Drop Rate Range: 1~400 drops/min (step: 1 drop/min)

Adjustable Volume Rate Range:1~1200 ml/h (when 1~99.9 ml/h, step: 0.1 ml/h; greater than 99.9 ml/h, step: 1 ml/h)

Flow Precision:Within±3% (using the IV set appointed by the manufacturer or calibrated high quality IV set) Mechanical precision: within±2%.

Purge Rate:800 ml/h

KVO Rate:1 ml/h (1~300 ml/h); 3 ml/h (greater than 300 ml/h);

Infusion Volume Range: 1 ml~9999.9 ml (step: 0.1 ml)

Maximum Accumulated Volume:9999.9 ml (step: 0.1 ml)

Time Range:1 min~9999 min (step: 1 min)

Occlusion Alarm Threshold:
High: 800 mmHg±200 mmHg (106.7kPa±26.7kPa)
Medium: 500 mmHg±100 mmHg (66.7kPa±13.3kPa)
Low: 300 mmHg±100 mmHg (40.7kPa±13.3kPa)

Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation,
Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.

Air Bubble Detector: Method: ultrasonic wave, sensitivity: >25 μL

Fuse: F1AL/250V ("F" indicate fast,"L" indicate low breaking capacity), 2 pcs (installed inside pump).

Power Supply: AC 85~265V, 50/60Hz;
Internal Battery:11.1V rechargeable li-ion battery. Capacity:>2000mAh;
the pump can work more than 4 hours at the flow rate of 25 ml/h after charging for
8 hours (Medium rate specified by GB 9706.27-2005).
Power: <40VA 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier