Customization: | Available |
---|---|
Classification: | Biochemical Apparatus |
Type: | Biochemistry Analyzer |
Still deciding? Get samples of US$ 3600/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
1. No touch mixing function, greatly reducing water consumption and decreasing carry-over.
2. Lower reagent consumption technology, greatly saving reagent's production, transportation and storage cost, and decreasing carry-over (On request, down to 80ul/test)
3. New cooling system, steadily keeping reagent chamber in 2-8ºC.
4. Auto perameter setting function.
Technical Specifications:
Model | DS-161 |
Operation | Random access |
Reading System | Direct reading system |
Method | End point, Kinetic, Fixed time, Bi-chromatic, Immunoturbidimetric, 1-2 reagent multistandard, reagent/serum blank, etc |
Assay Item | 36 assay items |
Throughput | 1 Reagent: 220 test/h (max); 2 Reagent: 160 test/h |
Sample Position | 50 postions , including standard, control stat; either serum cup or primary tube available |
Sample Volume | 1-100µL, 0.1µL/step |
Reagent Position | 36 |
Reagent Volume | R1 : 1µL-400µL, 1µL/step R2 : 1µL-400µL, 1µL/step |
Reagent/Sample Probe | With liquid level sensor, collision sensor , coating and automatic washing station |
Reaction Time | 0-999 seconds |
Cuvette | High quality UV-transmitted plastic cuvette, or quartz glass cuvette on request |
Cuvette Washing | 5 channels automatic washing system for cuvettes |
Alarm | Automatic alarm for malfuction (e.g: collision, reagent and distilled water insufficiency, waste container ful, etc) |
Calibration | Linear, Non-linear, Multi point, K factor |
Sample Dilution / Retest | Sample can be diluted and retested if results are out of range |
Wavelength | 340, 405, 450, 505, 546, 578, 620, 670nm(standard), 330, 380, 492, 510, 600, 630, 650, 660, 700, 750, 800, 810nm (optional two filters) |
Light Source | Halogen lamp |
Absorbance Resolution | 0.0001A |
Absorbance Accuracy | 0-0.5A: ±0.02A; 0.5-1.0A: ±0.04A; 1.0-1.5A: ±0.06A |
Repeatability(CV%) | ALT<3%, UREA<2.5%, TP<1.5% |
Quality Control | Levy jennings quality control program at 3 levels |
Bar Code | Optional |
Printer | Multiple report formats available |
Other | Tele-diagnostic, bi-direction interface to LIS syste, etc |
Language | English , French , Spanish , German , Russian , etc |
System | Window XP or Vista ; Window 7 |
Power Supply | 220V/50Hz, or 110V/60Hz |
Dimension | 65 x 53 x 52cm |
Weight | 45 Kg |