DM7000 is a defibrillation device, which can meet your clinical needs from Basic Life Support (BLS) to Advanced Cardiac Life Support (ACLS).
Display | |
Screen Type | High-resolution display |
Screen Size | 7 inches(17.7 cm) diagonally |
Sweep Speed | 25mm/sec |
Information | Heart Rate, Lead/Pads, Alarm On/Off, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy. |
Defibrillator | |
Waveform | Biphasic |
Charge Time | Less than 7 seconds with a new fully charged battery. |
Energy Display | Monitor display indicates both selected and delivered energy. |
Charge Prompt Type | Voice and visual prompts. |
Electrode Impedance Measurement Range | 0-250 ohms. |
ECG Monitoring | |
Patient Connection | 3-lead ECG cable, or 5-lead ECG cable, paddles. |
Lead Selection | Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V. |
ECG Size | 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor. |
Heart Rate | 20-300BPM. |
Heart Rate Alarm | On/Off displayed on monitor, user-selectable. |
Smart Alarms | Beeper/voice prompts indicate shockable rhythm. |
Battery | |
Type | Rechargeable, Ni-MH battery, 12V. |
Operating Time | For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions. |
SpO2 Module | |
Measurement Range | 30~100%, ±2% between 80%~90%, others ±5% |
Alarm Range | User set high limit and low limit. |
Alarm Accuracy | ±10% within setting values. |
Alarm time Accuracy | less than 12 sec. |
Recorder | |
Paper | 50mm thermal. |
Speed | 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay. |
Printing Method | High-resolution, thermal print head. |
Print-out Modes | Manual or automatic, user-configurable. |
On/Off Control | Front panel and paddle. |
Automatic Function | 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge. |
AED Mode | |
AED Function | Auto analyze and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts. |
Shockable Rhythms | Ventricular fibrillation with amplitude >=200uV, Ventricular tachycardia with rates >=140bpm, and QRS complex wave duration >=140ms. |
Charge Control | Control on device front panel, press key on paddle. |
Prompts | Voice and visual prompts. |
Manual Mode | |
Energy Selection | Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules. |
Synchronized Mode | Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monitor. |