Classification: Imaging Diagnostic Equipment
Type: X Ray Equipment
Certification: CE, EEC, MSDS, ISO13485
Group: All People
Product Name: X-ray Machine
Kv: 50~120kv
Customization:
Diamond Member Since 2009

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
SF100BG
Frequency
50Hz
Power Supply
220 V
Voltage
180-240V
Focal Distance
430X430mm
Lead Time
Within 7 Days
Warranty
12 Months
Transport Package
Wooden Case
Specification
CE, TUV, ISO
Trademark
PIOWAY
Origin
China

Product Description

100mA Medical Diagnostic fied bed X-Ray Machine (SF100BG)
100mA Medical Diagnostic Fied Bed X-ray Machine (SF100BG)
General Description:
Model SF100BG 100mA medical photography x-ray unit
can be used for head, chest, belly, arms and legs, bone in lying position, stand position, side position of photograph.

Model SF100BG 100mA medical photography X-ray unit
can use for ordinary photograph and grid photography.


Features:
Used for general radiography and ray-filter radiography.
1. Single bed with single bulb
2. Good design,complete functions and reasonable structure.
3. High-pressure system march-past structure. Full-wave rectification and high voltage generator, independent x-ray
tube assembly (tangential type pipe sleeve), large power output, stable performance.
4. Power supply voltage (V), photography (kV), stepless continuous adjustable. Equipped with
voltage stabilizer, space charge compensator, kV compensator and power supply compensator so that the X-ray
output of this unit can be kept constant.
5. Timer circuit, exact time control. kV, mA and s capacity interlocking control system
6. Flat photographic bed, with vibrating type ray-filter.
7. Only track, easy to install


Main Technical Conditions:
Mains Voltage:220V/380V ±10% AC ; Phase: Single Phase
Supply Capacity:7kVA
Power Frequency:50Hz ±1%
Power Inner Resistance: not more than 0.6 for 220V; not more than 2 for 380V
Main Technical Specifications
Maximum rated capacity Current(mA) Voltage (kvp) Exposure time(s)
15 90 0.04-6.3
30 90 0.04-6.3
60 90 0.04-6.3
100 85 0.04~2.5
Timer 0.04s ~6.3s in 22 shifts, electronic type
Photographic bed Bed face (L*W*H) 1900*695*700mm
Ray-filter:
1. grid density: N28;
2. convergence distance:100cm;
3. grid ratio: r8
High voltage transformer unit Capacity 7kvA; Max. DC output voltage 90kv; Max.DC output current 100mA
Pillar of x-ray source unit 1. moving in length along the bed: >1350mm
2. move in breadth: >360mm
3. moving up and down: 720-1800mm
Specification of x ray tube XD4-2.9/100 small focus 1.8mm, big focus 4.3mm


Paching Datas:

Gross weight 600kg
N.W. 500kg
Packing dimension 218cm*80cm*113cm, 1.97CBM


Detailed Images:    
 

100mA Medical Diagnostic Fied Bed X-ray Machine (SF100BG)
100mA Medical Diagnostic Fied Bed X-ray Machine (SF100BG)
100mA Medical Diagnostic Fied Bed X-ray Machine (SF100BG)
100mA Medical Diagnostic Fied Bed X-ray Machine (SF100BG)



Contact us:
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now